Victron Energy
Victron Phoenix VE.Direct Schuko 12/1200 inverter 1000 W
Victron Phoenix Inverter 1000 W with Bluetooth Option (12 V Battery System)
SinusMax – cutting-edge technology
The Phoenix inverter series was developed for commercial use; it is suitable for a wide range of applications. The uncompromising goal of the development was to create an inverter with a clean sine wave output and high efficiency. By applying the latest hybrid RF technology, it was possible to present a high-quality product with compact dimensions and low weight that can easily deliver any desired power output.
VE.Direct / Bluetooth dongle connection: Convenient device monitoring with your smartphone
The inverter can be connected to a PC or mobile phone using the VE.Direct connection.
It's also possible to monitor the device's status using your mobile phone. Simply connect the dongle.
Highest take-off performance
A key feature of SinusMax technology is its particularly high starting power. This is not possible with conventional HF technology. Phoenix inverters are capable of handling the high starting currents of refrigeration compressors, tool motors, and similar devices. Load transfer to other AC power sources: The automatic load transfer switch. For lower power requirements, we recommend the Filax automatic load transfer switch. This allows computers and other sensitive electronic devices to continue operating virtually uninterrupted, as the switching times are very short (less than 20 ms).
ECO mode
In ECO mode, the inverter switches to standby as soon as the load drops below a preset level (minimum load: 15 W). In standby mode, the inverter then switches on for a short period of time (adjustable default setting: every 2.5 seconds). If the load exceeds a preset threshold, the inverter remains on.
Proven reliability
Complete bridging with a toroidal transformer topology has proven successful for years. The inverters are short-circuit proof and protected against overheating (whether caused by overload or ambient temperature).
Fully configurable:
- Thresholds for triggering and resetting alarms when the battery charge level is low.
- Thresholds for shutdown and restart at low battery voltage levels.
- Dynamic shutdown: load-dependent shutdown threshold
- Output voltage 210 - 245 V
- Frequency 50 Hz or 60 Hz
- Threshold for ECO mode on/off and ECO mode sensor
- Monitoring: input and output voltage, % load and alarms